What is the current version of NFPA 72?

Only the 2016 NFPA 72 Handbook has it all: The full text of the 2016 edition of NFPA 72 provides the latest requirements for the application, installation, location, performance, and inspection, testing, and maintenance of fire alarm and mass notification systems and components.

Is NFPA 72 mandatory?

No. NFPA 72 only provides requirements for the installation, performance, testing, inspection, and maintenance of the fire alarm system. NFPA 101®, Life Safety Code® and other codes determine whether a fire alarm system is required in a given occupancy.

What NFPA 74?

In 1989, NFPA 74 Standard for the Installation, Maintenance and Use of Household Fire Warning Equipment, required newly constructed residential homes to have interconnected (hard- wired) smoke alarms on every level of the home and outside the sleeping areas.

What NFPA 13?

NFPA 13R is a residential sprinkler design standard focused on low-rise residential occupancies. The Standard’s intent is to provide a sprinkler system that aids in the control of residential fires and provides improved protection against injury and life loss in multi-family dwellings.

What NFPA 24?

NFPA 24 helps ensure water supplies are available in a fire emergency, with detailed requirements for the installation of private fire service mains and their appurtenances supplying private hydrants and water-based fire protection systems.

IMPORTANT:  Who is the highest paid firefighter in California?

Do fire alarms need two phone lines?

The requirements for fire alarm signaling have been well defined by the National Fire Protection Association (NFPA) 72 National Fire Alarm Code. … Those businesses who have switched have usually had to keep two POTS phone lines in order to meet the monitoring requirements of their fire alarm systems.

Is fire alarm wiring required to be in conduit?

According to the National Fire Protection Association (NFPA) regulations and National Electric Code (NEC) articles, any wiring that exists in non-accessible areas or below seven feet must be installed in metallic conduit.

What does the administrative section of NFPA 72 cover?

1.1. 1 NFPA 72 covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components.

Is code for fire alarm system?

(1) IS:2189 – 1962 Code of Practice for Automatic Fire Alarm System.

Where should smoke alarms not be placed?

Where the temperatures are regularly below 40°F (4° C) or above 100° F (38° C) including unheated buildings, outdoor rooms, porches, or unfinished attics or basements. In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm directly over the stove or range.

What is the maximum mounting height of a smoke detector?

Smoke Detector & Heat Detector Mounting Heights

Detector Type Maximum Ceiling Height (m) Cat L/P
Smoke Detectors 10.5 Meters (12.5 meters for 10% of Ceiling)
CO Point Detectors 10.5 Meters (12.5 meters for 10% of Ceiling)
Optical Beam Detectors 25 Meters (25 meters for 10% of Ceiling)